ID bài viết: 000034690 Loại nội dung: Cài đặt & Thiết lập Lần duyệt cuối: 12/07/2021

Làm cách nào để định cấu hình Raid 10/50/60 trên bảng mạch máy chủ của tôi

Môi Trường

WindowsServer2016

BUILT IN - ARTICLE INTRO SECOND COMPONENT
Tóm tắt

Cách cấu hình Raid 10 trên bảng mạch Máy chủ Intel dựa trên HII/UEFI

Mô tả

Tôi không thể truy cập tiện ích cấu hình RAID trong khi khởi động để tạo Raid 10

Độ phân giải

The Intel® Server Board S1200SPS uses Human Interface Infrastructure Configuration Utility (HII CU) when the boot mode is set to UEFI (Unified Extensible Firmware Interface). This is why neither the Ctrl+G nor Ctrl+R and Ctrl+E or Ctrl+I are available in a pre-boot environment. To configure raid on Intel server board that uses HII CU, below are the steps.

1. Press F2 when system POST and enter system BIOS. 
2. Go to Boot Maintenance Manager 
3. Go to Advanced Boot Options 
4. Under Boot Mode, select UEFI 
5. Press F10 to save changes and reboot back to BIOS 
6. Go to Advanced 
7. Select Mass Storage Controller configuration 
8. Select SATA Port Configuration 
9. Under AHCI Capable SATA Controller, select RAID Mode 
10. Under AHCI Capable RAID Options, select Intel ESRT2 
11. Press F10 to save changes and reboot back to BIOS 
12. Go to Advance 
13. Go to PCI Configuration 
14. Go to UEFI Option ROM Control 
15. Scroll at the very bottom and you should see Storage Controller Intel Embedded Server Raid Technology 2, select this and press Enter 
16. In the Configuration Option screen, select Virtual Drive Management 
17. On the next screen select Create Configuration 

To configure a Raid 10/50/60 proceed with the following steps

For Raid 10, use two drives
For Raid 50, use at least three drives
For Raid 60, use at least three drives

18. On the next screen, under Select Raid Level, select Raid 10 
19. On the same screen, highlight Select Drives and press Enter 
20. On the next screen, select the drives (make sure they have X mark on the box next to them) 21. Scroll at the bottom and select Apply change and press Enter 
22. On the next screen, scroll down and select Save Configuration 
23. Select Yes on the next screen.  
24. Repeat step 20. From the drives that are available in the left pane, choose an additional group of drives and add the drives to the existing array.

For more details refer to the Intel® RAID Software User Guide - Pages 46 & 90.

Các sản phẩm liên quan

Bài viết này áp dụng cho 1 sản phẩm

Nội dung gốc bằng tiếng Anh trên trang này vừa do con người vừa do máy dịch. Nội dung này chỉ để cung cấp thông tin chung và giúp quý vị thuận tiện. Quý vị không nên tin đây là thông tin hoàn chỉnh hoặc chính xác. Nếu có bất kỳ mâu thuẫn nào giữa bản tiếng Anh và bản dịch của trang này, thì bản tiếng Anh sẽ chi phối và kiểm soát. Xem phiên bản tiếng Anh của trang này.